En

LT series semi-hermetic two-stage frequency conversion screw refrigeration compressor

LT-S-V and LT-S-IVX two-stage frequency conversion series compressor developed by Hanbell has accumulated many years of experience in refrigeration market. LT-S-V means two-stage variable frequency compressor, and LT-S-IVX means fully configured two-stage variable frequency compressor with frequency converter. In addition to inheriting the characteristics of normal LT model such as full-loading high efficiency under high pressure ratio and large differential pressure, wide operating temperature range, the new series products also introduces frequency conversion technology to improve the partial-loading efficiency, so as to improve the comprehensive efficiency of the compressor and reduce the operating costs. Through the frequency conversion technology, the capacity regulation accuracy is greatly improved, and the output cooling capacity can be effectively controlled, so as to reduce the fluctuation of warehouse temperature, reduce the wasting consumption, and further enhance the comprehensive competitiveness of the product.

 

In summary, LT-S-V and LT-S-IVX are highly suitable for freezing market demand. They are suitable for low-temperature refrigerators, quick-frozen tunnels and quick freezing storehouses, as well as other low temperature applications.


Features
Model Specification

High efficiency and energy saving

Adopt frequency conversion technology; the comprehensive energy efficiency is increased by more than 20% compared with the fixed frequency

 

Precise temperature control

It can realize step-less adjustment, accurately control the required temperature, improve the quality of frozen products and reduce wasted consumption.

 

Quick frozen

Wide temperature range of full load operation with frequency rise technology, which can greatly improve the cooling speed.

 

Cooling capacity increase

The maximum capacity of single compressor can reach 300Hp, which maximum can meet the cooling requirement of 2.5 ton screw freezer

Smooth start-up and stop

Full frequency control, eliminate the impact of starting current and shorten the reverse time of shutdown


Model


LT-S-V


Nominal Hp
  80Hz

Displacement

(Full loading)

Frequency range

Motor

Lubrication

Weight Kg

Strength


Low pressure m3/h

High pressure m3/h

Type

Starting

Voltage(V) 80Hz

Insulation

Protection


Bar


LT-S-36/16-V

80

358

158

2080Hz

3 phase 2 pole squirrel cage induction motor

VFD

380

Level F

PTC+NTC

Differential pressure oil supply

620

35


LT-S-50/22-V

120

506

219

620


LT-S-72/33-V

160

720

331

1200


LT-S-88/41-V

200

881

411

1230


LT-S-104/50-V

240

1042

501

1450


LT-S-135/63-V

300

1296

634

1490




Fully configured compressor with convertor specification

Model

Compressor

Frequency   controller

Frequency   convertor

Base

LT-S-36/16-IVA

LT-S-36/16-V

HB-IC-100

HB-INV-100P

100P Base

LT-S-36/16-IVB

HB-INV-120P

120P&150P&   180P&220P Base

LT-S-50/22-IVA

LT-S-50/22-V

HB-IC-100

HB-INV-120P

LT-S-50/22-IVB

HB-INV-150P

LT-S-72/33-IVA

LT-S-72/33-V

HB-IC-100

HB-INV-180P

LT-S-72/33-IVB

HB-INV-220P

LT-S-88/41-IVA

LT-S-88/41-V

HB-IC-100

HB-INV-220P

LT-S-88/41-IVB

HB-INV-250P

250P&   300P&380P Base

LT-S-104/50-IVA

LT-S-104/50-V

HB-IC-100

HB-INV-250P

LT-S-104/50-IVB

HB-INV-300P

LT-S-135/63-IVA

LT-S-135/63-V

HB-IC-100

HB-INV-300P

LT-S-135/63-IVB

HB-INV-380P

 


Catalogue & Technical Manual

Name

Release Time

Download

Drawing

Name

Release Time

Download